0e5b5b46a8167344583a5fa1efaf29974b65f32b

Copy-paste error from 9edcc44
.
Spotted with `cd test && ./generate-xml.sh test-frames`
--- test-frames/manual_frame2.xml 2016-05-09 00:19:44.000000000 +0200
+++ test-frames/manual_frame2.xml.new 2016-05-09 01:09:09.000000000 +0200
@@ -17,7 +17,7 @@
<DataRecord id="1">
<Function>Actual value</Function>
<Unit>reserved but historic</Unit>
- <Value>135</Value>
+ <Value>1</Value>
</DataRecord>
</MBusData>
libmbus: M-bus Library from Raditex Control (http://www.rscada.se) libmbus is an open source library for the M-bus (Meter-Bus) protocol. The Meter-Bus is a standard for reading out meter data from electricity meters, heat meters, gas meters, etc. The M-bus standard deals with both the electrical signals on the M-Bus, and the protocol and data format used in transmissions on the M-Bus. The role of libmbus is to decode/encode M-bus data, and to handle the communication with M-Bus devices. For more information see http://www.rscada.se/libmbus
Description
Languages
C
95.8%
Shell
1.8%
Makefile
1.5%
XSLT
0.5%
M4
0.3%