184 lines
4.6 KiB
Arduino
Raw Normal View History

2022-12-15 15:26:57 +01:00
/*
Modbus RTU Client Kitchen Sink
This sketch creates a Modbus RTU Client and demonstrates
how to use various Modbus Client APIs.
Circuit:
- MKR board
- MKR 485 shield
- ISO GND connected to GND of the Modbus RTU server
- Y connected to A/Y of the Modbus RTU server
- Z connected to B/Z of the Modbus RTU server
- Jumper positions
- FULL set to OFF
- Z \/\/ Y set to ON
created 18 July 2018
by Sandeep Mistry
*/
#include <ArduinoRS485.h> // ArduinoModbus depends on the ArduinoRS485 library
#include <ArduinoModbus.h>
int counter = 0;
void setup() {
Serial.begin(9600);
while (!Serial);
Serial.println("Modbus RTU Client Kitchen Sink");
// start the Modbus RTU client
if (!ModbusRTUClient.begin(9600)) {
Serial.println("Failed to start Modbus RTU Client!");
while (1);
}
}
void loop() {
writeCoilValues();
readCoilValues();
readDiscreteInputValues();
writeHoldingRegisterValues();
readHoldingRegisterValues();
readInputRegisterValues();
counter++;
delay(5000);
Serial.println();
}
void writeCoilValues() {
// set the coils to 1 when counter is odd
byte coilValue = ((counter % 2) == 0) ? 0x00 : 0x01;
Serial.print("Writing Coil values ... ");
// write 10 Coil values to (slave) id 42, address 0x00
ModbusRTUClient.beginTransmission(42, COILS, 0x00, 10);
for (int i = 0; i < 10; i++) {
ModbusRTUClient.write(coilValue);
}
if (!ModbusRTUClient.endTransmission()) {
Serial.print("failed! ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.println("success");
}
// Alternatively, to write a single Coil value use:
// ModbusRTUClient.coilWrite(...)
}
void readCoilValues() {
Serial.print("Reading Coil values ... ");
// read 10 Coil values from (slave) id 42, address 0x00
if (!ModbusRTUClient.requestFrom(42, COILS, 0x00, 10)) {
Serial.print("failed! ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.println("success");
while (ModbusRTUClient.available()) {
Serial.print(ModbusRTUClient.read());
Serial.print(' ');
}
Serial.println();
}
// Alternatively, to read a single Coil value use:
// ModbusRTUClient.coilRead(...)
}
void readDiscreteInputValues() {
Serial.print("Reading Discrete Input values ... ");
// read 10 Discrete Input values from (slave) id 42, address 0x00
if (!ModbusRTUClient.requestFrom(42, DISCRETE_INPUTS, 0x00, 10)) {
Serial.print("failed! ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.println("success");
while (ModbusRTUClient.available()) {
Serial.print(ModbusRTUClient.read());
Serial.print(' ');
}
Serial.println();
}
// Alternatively, to read a single Discrete Input value use:
// ModbusRTUClient.discreteInputRead(...)
}
void writeHoldingRegisterValues() {
// set the Holding Register values to counter
Serial.print("Writing Holding Registers values ... ");
// write 10 coil values to (slave) id 42, address 0x00
ModbusRTUClient.beginTransmission(42, HOLDING_REGISTERS, 0x00, 10);
for (int i = 0; i < 10; i++) {
ModbusRTUClient.write(counter);
}
if (!ModbusRTUClient.endTransmission()) {
Serial.print("failed! ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.println("success");
}
// Alternatively, to write a single Holding Register value use:
// ModbusRTUClient.holdingRegisterWrite(...)
}
void readHoldingRegisterValues() {
Serial.print("Reading Input Register values ... ");
// read 10 Input Register values from (slave) id 42, address 0x00
if (!ModbusRTUClient.requestFrom(42, HOLDING_REGISTERS, 0x00, 10)) {
Serial.print("failed! ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.println("success");
while (ModbusRTUClient.available()) {
Serial.print(ModbusRTUClient.read());
Serial.print(' ');
}
Serial.println();
}
// Alternatively, to read a single Holding Register value use:
// ModbusRTUClient.holdingRegisterRead(...)
}
void readInputRegisterValues() {
Serial.print("Reading input register values ... ");
// read 10 discrete input values from (slave) id 42,
if (!ModbusRTUClient.requestFrom(42, INPUT_REGISTERS, 0x00, 10)) {
Serial.print("failed! ");
Serial.println(ModbusRTUClient.lastError());
} else {
Serial.println("success");
while (ModbusRTUClient.available()) {
Serial.print(ModbusRTUClient.read());
Serial.print(' ');
}
Serial.println();
}
// Alternatively, to read a single Input Register value use:
// ModbusRTUClient.inputRegisterRead(...)
}