2024-11-11 17:59:23 +01:00

114 lines
3.8 KiB
SQL

create or replace view pv_power_v as
select time,
cast(values->'PowerActive'->>'value' as float) as power,
values->'Status'->>'status' as status,
device
from measurements
where application = 'PV';
create or replace view pv_total_import_v as
select time,
cast(values->'Power'->>'value' as float) as power,
device
from measurements
where application = 'Power' and
device = 'Total' and
attributes->>'Status' = 'Ok';
create or replace view power_v as
select time,
cast(values->'Power'->>'value' as float) as power,
device
from measurements
where application = 'Power' and
attributes->>'Status' = 'Ok';
create or replace view temperature_heating_v as
select time,
cast(values->'Value'->>'value' as float) as temperature,
device
from measurements
where application = 'Temperature Heating';
create or replace view gas_v as
select time,
cast(values->'Volume'->>'value' as float) as volume,
device
from measurements
where application = 'Gas' and
attributes->>'Status' = 'Ok';
create or replace view temperature_v as
select time,
cast(values->'Value'->>'value' as float) as temperature,
device
from measurements
where application in ('Temperature Multisensor', 'Temperature Shelly Plus HT')
union
select time,
cast(values->'Temperature'->>'value' as float) as temperature,
device
from measurements
where application = 'Zigbee2MQTT Hottis Eupenstr.' and
attributes->>'DeviceModel' in ('WSDCGQ11LM', 'WSDCGQ01LM');
create or replace view temperature2_v as
select time,
cast(values->'Value'->>'value' as float) as temperature,
device
from measurements
where application = 'Temperature Wago';
create or replace view humidity_v as
select time,
cast(values->'Value'->>'value' as float) as humidity,
device
from measurements
where application in ('Humidity Multisensor')
union
select time,
cast(values->'Humidity'->>'value' as float) as temperature,
device
from measurements
where application = 'Zigbee2MQTT Hottis Eupenstr.' and
attributes->>'DeviceModel' in ('WSDCGQ11LM', 'WSDCGQ01LM');
create or replace view soil_v as
select time,
cast(values->'Water'->>'value' as float) as water,
cast(values->'Conductance'->>'value' as float) as conductance,
cast(values->'Temperature'->>'value' as float) as temperature,
device
from measurements
where application = 'de-hottis-app01' and attributes->>'DeviceType' = 'dragino-lse01';
create or replace view co2_v as
select time,
cast(m.values->'CO2concentration'->>'value' as float) as co2concentration,
cast(m.values->'Humidity'->>'value' as float) as humidity,
cast(m.values->'Temperature'->>'value' as float) as temperature,
cast(m.values->'Brightness'->>'value' as int) as brightness,
m.device as device,
d.attributes->>'Label' as label
from measurements m, devices d
where m.application = 'de-hottis-app01' and
m.attributes->>'DeviceType' = 'hottis-scd30' and
m.device = d.label;
create or replace view locative_v as
select time,
device as person,
values->'Location'->>'value' as location,
values->'Trigger'->>'value' as direction
from measurements
where application = 'Locative';
create or replace view router_v as
select time,
device,
cast(values->'wan-in'->>'value' as int) as wanInOctetsPerSeconds,
cast(values->'wan-out'->>'value' as int) as wanOutOctetsPerSeconds
from measurements
where application = 'SNMP' and device = '172.16.3.1';