Files
universal-data-ingest/queries/hottis.sql
Wolfgang Hottgenroth 3b69e1e2af
All checks were successful
ci/woodpecker/push/woodpecker Pipeline was successful
car_values_v
2025-12-15 17:28:15 +01:00

182 lines
6.8 KiB
SQL

create or replace view pv_power_v as
select time,
cast(values->'PowerActive'->>'value' as float) as power,
values->'Status'->>'status' as status,
device
from measurements
where application = 'PV';
create or replace view pv_total_import_v as
select time,
cast(values->'Power'->>'value' as float) as power,
device
from measurements
where application = 'Power' and
device = 'Total' and
attributes->>'Status' = 'Ok';
create or replace view power_v as
select time,
cast(values->'Power'->>'value' as float) as power,
device
from measurements
where application = 'Power' and
attributes->>'Status' = 'Ok';
create or replace view temperature_heating_v as
select time,
cast(values->'Value'->>'value' as float) as temperature,
device
from measurements
where application = 'Temperature Heating';
create or replace view gas_v as
select time,
cast(values->'Volume'->>'value' as float) as volume,
device
from measurements
where application = 'Gas' and
attributes->>'Status' = 'Ok';
create or replace view temperature_v as
select time,
cast(values->'Value'->>'value' as float) as temperature,
device
from measurements
where application in ('Temperature Multisensor', 'Temperature Shelly Plus HT')
union
select time,
cast(values->'Temperature'->>'value' as float) as temperature,
device
from measurements
where application = 'Zigbee2MQTT Hottis Eupenstr.' and
attributes->>'DeviceModel' in ('WSDCGQ11LM', 'WSDCGQ01LM');
create or replace view voltage_v as
select time,
cast(values->'Voltage'->>'value' as float) / 1000 as voltage,
device
from measurements
where application = 'Zigbee2MQTT Hottis Eupenstr.' and
attributes->>'DeviceModel' in ('WSDCGQ11LM', 'WSDCGQ01LM');
create or replace view temperature2_v as
select time,
cast(values->'Value'->>'value' as float) as temperature,
device
from measurements
where application = 'Temperature Wago';
create or replace view humidity_v as
select time,
cast(values->'Value'->>'value' as float) as humidity,
device
from measurements
where application in ('Humidity Multisensor')
union
select time,
cast(values->'Humidity'->>'value' as float) as temperature,
device
from measurements
where application = 'Zigbee2MQTT Hottis Eupenstr.' and
attributes->>'DeviceModel' in ('WSDCGQ11LM', 'WSDCGQ01LM');
create or replace view soil_v as
select time,
cast(values->'Water'->>'value' as float) as water,
cast(values->'Conductance'->>'value' as float) as conductance,
cast(values->'Temperature'->>'value' as float) as temperature,
device
from measurements
where application = 'de-hottis-app01' and attributes->>'DeviceType' = 'dragino-lse01';
create or replace view co2_v as
select time,
cast(m.values->'CO2concentration'->>'value' as float) as co2concentration,
cast(m.values->'Humidity'->>'value' as float) as humidity,
cast(m.values->'Temperature'->>'value' as float) as temperature,
cast(m.values->'Brightness'->>'value' as int) as brightness,
m.device as device,
d.attributes->>'Label' as label
from measurements m, devices d
where m.application = 'de-hottis-app01' and
m.attributes->>'DeviceType' = 'hottis-scd30' and
m.device = d.label;
create or replace view locative_v as
select time,
device as person,
values->'Location'->>'value' as location,
values->'Trigger'->>'value' as direction
from measurements
where application = 'Locative';
create or replace view router_v as
select time,
device,
cast(values->'wan-in'->>'value' as int) as wanInOctetsPerSeconds,
cast(values->'wan-out'->>'value' as int) as wanOutOctetsPerSeconds
from measurements
where application = 'SNMP' and device = '172.16.3.1';
create or replace view lora_sht21_v as
select time,
cast(values->'Humidity'->>'value' as float) as humidity,
cast(values->'Temperature'->>'value' as float) as temperature,
m.device as device,
d.attributes->>'Label' as label
from measurements m, devices d
where m.application = 'de-hottis-app01' and
m.attributes->>'DeviceType' = 'hottis-gy21' and
m.device = d.label;
create or replace view ntp_server_snmp_v as
select time,
device,
cast(values->'load1'->>'value' as float) as laLoad1,
cast(values->'lan-in'->>'value' as int) as lanInOctetsPerSeconds,
cast(values->'lan-out'->>'value' as int) as lanOutOctetsPerSeconds
from measurements
where application = 'SNMP' and device = '172.16.13.10';
create or replace view ntp_server_variables_v as
select time,
device,
cast(values->'rootdisp'->>'value' as float) as rootdisp
from measurements
where application = 'TSM' and device = '172.16.13.10';
-- Status string `unit:"" json:"status"`
-- Timestamp string `unit:"" json:"timestamp"`
-- VoltageL1 float32 `unit:"V" json:"voltageL1"`
-- VoltageL2 float32 `unit:"V" json:"voltageL2"`
-- VoltageL3 float32 `unit:"V" json:"voltageL3"`
-- CurrentL1 float32 `unit:"A" json:"currentL1"`
-- CurrentL2 float32 `unit:"A" json:"currentL2"`
-- CurrentL3 float32 `unit:"A" json:"currentL3"`
-- PowerL1 float32 `unit:"W" json:"powerL1"`
-- PowerL2 float32 `unit:"W" json:"powerL2"`
-- PowerL3 float32 `unit:"W" json:"powerL3"`
-- TotalImportEnergy float32 `unit:"Wh" json:"totalImportEnergy"`
-- TotalExportEnergy float32 `unit:"Wh" json:"totalExportEnergy"`
-- Cnt int `unit:"" json:"cnt"`
create or replace view car_values_v as
select time,
cast(values->'VoltageL1'->>'value' as float) as voltage_l1,
cast(values->'VoltageL2'->>'value' as float) as voltage_l2,
cast(values->'VoltageL3'->>'value' as float) as voltage_l3,
cast(values->'CurrentL1'->>'value' as float) as current_l1,
cast(values->'CurrentL2'->>'value' as float) as current_l2,
cast(values->'CurrentL3'->>'value' as float) as current_l3,
cast(values->'PowerL1'->>'value' as float) as power_l1,
cast(values->'PowerL2'->>'value' as float) as power_l2,
cast(values->'PowerL3'->>'value' as float) as power_l3,
cast(values->'TotalImportEnergy'->>'value' as float) as total_import_energy,
cast(values->'TotalExportEnergy'->>'value' as float) as total_export_energy,
values->'Status'->>'value' as status,
device
from measurements
where application = 'Car';