tsm
This commit is contained in:
parent
084645f002
commit
3a56309b9f
@ -156,6 +156,20 @@
|
||||
"unitSelector": "C:%"
|
||||
}
|
||||
}
|
||||
},
|
||||
{
|
||||
"topics": [ "tsm" ],
|
||||
"handler": "SVEJ",
|
||||
"id": "SVEJ5",
|
||||
"config": {
|
||||
"databaseConnStr": "",
|
||||
"attributes": {
|
||||
"application": "Timeserver Monitoring",
|
||||
"deviceSelector": "J:$.label",
|
||||
"valueSelector": "J:$.variables.rootdisp.value",
|
||||
"unitSelector": "J:$.variables.rootdisp.unit"
|
||||
}
|
||||
}
|
||||
}
|
||||
],
|
||||
"archiver": {
|
||||
|
1
migration/.gitignore
vendored
1
migration/.gitignore
vendored
@ -1 +0,0 @@
|
||||
.venv
|
@ -1,38 +0,0 @@
|
||||
import psycopg2
|
||||
from loguru import logger
|
||||
|
||||
try:
|
||||
srcConn = psycopg2.connect(database="level_monitoring_berresheim")
|
||||
srcConn.autocommit = False
|
||||
destConn = psycopg2.connect(database="udi-berresheim")
|
||||
destConn.autocommit = False
|
||||
|
||||
with srcConn.cursor() as srcCur, destConn.cursor() as destCur:
|
||||
srcCur.execute("select time, application_name, raw_level, level, status, battery from measurement_t")
|
||||
for srcObj in srcCur:
|
||||
timestamp = srcObj[0]
|
||||
deviceName = srcObj[1]
|
||||
rawLevel = srcObj[2]
|
||||
level = srcObj[3]
|
||||
status = srcObj[4]
|
||||
battery = srcObj[5]
|
||||
|
||||
logger.info(f"{timestamp=}, {deviceName=}, {rawLevel=}, {level=}, {status=}, {battery=}")
|
||||
|
||||
destTime = timestamp
|
||||
destApplication = "de-hottis-level-monitoring"
|
||||
destDevice = "eui-a84041a2c18341d6"
|
||||
destAttributes = '{"ApplicationId":"de-hottis-level-monitoring", "DeviceType":"dragino-ldds75", "Status":"' + status + '","Hint": "Migrated"}'
|
||||
destValues = '{"Battery":{"unit":"V","label":"Battery","value":' + str(battery) + ',"variable":"Voltage"}, "Distance":{"unit":"mm","label":"Distance","variable":"Level","value":' + str(rawLevel) + '}, "CorrectedDistance":{"unit":"mm", "label":"CorrectedDistance", "variable":"Level","value":' + str(level) + '}}'
|
||||
logger.info(f"{destTime=}, {destApplication=}, {destDevice=}, {destAttributes=}, {destValues=}")
|
||||
|
||||
destCur.execute("insert into measurements (time, application, device, attributes, values) values(%s, %s, %s, %s, %s)",
|
||||
(destTime, destApplication, destDevice, destAttributes, destValues))
|
||||
destConn.commit()
|
||||
finally:
|
||||
if srcConn:
|
||||
srcConn.close()
|
||||
if destConn:
|
||||
destConn.close()
|
||||
|
||||
|
@ -1,79 +0,0 @@
|
||||
import psycopg2
|
||||
from loguru import logger
|
||||
import os
|
||||
|
||||
srcPgHost = os.environ["SRC_PGHOST"]
|
||||
srcPgUser = os.environ["SRC_PGUSER"]
|
||||
srcPgPassword = os.environ["SRC_PGPASSWORD"]
|
||||
srcPgDatabase = os.environ["SRC_PGDATABASE"]
|
||||
destPgHost = os.environ["DEST_PGHOST"]
|
||||
destPgUser = os.environ["DEST_PGUSER"]
|
||||
destPgPassword = os.environ["DEST_PGPASSWORD"]
|
||||
destPgDatabase = os.environ["DEST_PGDATABASE"]
|
||||
|
||||
try:
|
||||
srcConn = psycopg2.connect(
|
||||
host=srcPgHost,
|
||||
dbname=srcPgDatabase,
|
||||
user=srcPgUser,
|
||||
password=srcPgPassword,
|
||||
sslmode='require'
|
||||
)
|
||||
srcConn.autocommit = False
|
||||
|
||||
destConn = psycopg2.connect(
|
||||
host=destPgHost,
|
||||
dbname=destPgDatabase,
|
||||
user=destPgUser,
|
||||
password=destPgPassword,
|
||||
sslmode='require'
|
||||
)
|
||||
destConn.autocommit = False
|
||||
|
||||
with srcConn.cursor() as srcCur, destConn.cursor() as destCur:
|
||||
srcCur.execute("select time, deviceid, status, state, importenergyactive, importenergyreactive, exportenergyactive, exportenergyreactive, powerapparent, poweractive, powerreactive, powerdemandpositive, powerdemandreverse, factor, angle, voltage, current, powerdemand from pv_power_measurement_t order by time")
|
||||
for srcObj in srcCur:
|
||||
timestamp = srcObj[0]
|
||||
deviceName = srcObj[1]
|
||||
status = srcObj[2]
|
||||
state = srcObj[3]
|
||||
importenergyactive = srcObj[4]
|
||||
importenergyreactive = srcObj[5]
|
||||
exportenergyactive = srcObj[6]
|
||||
exportenergyreactive = srcObj[7]
|
||||
powerapparent = srcObj[8]
|
||||
poweractive = srcObj[9]
|
||||
powerreactive = srcObj[10]
|
||||
powerdemandpositive = srcObj[11]
|
||||
powerdemandreverse = srcObj[12]
|
||||
factor = srcObj[13]
|
||||
angle = srcObj[14]
|
||||
voltage = srcObj[15]
|
||||
current = srcObj[16]
|
||||
powerdemand = srcObj[17]
|
||||
|
||||
|
||||
logger.info(f"{timestamp=}, {deviceName=}")
|
||||
|
||||
destTime = timestamp
|
||||
destApplication = "PV"
|
||||
destDevice = "Powermeter"
|
||||
destAttributes = f"{{\"ApplicationId\":\"PV\", \"Status\":\"{status}\",\"Hint\": \"Migrated\"}}"
|
||||
destValues = f"{{\"Cnt\": {{\"unit\": \"\", \"label\": \"\", \"value\": \"-1\", \"variable\": \"Cnt\"}}, \"Angle\": {{\"unit\": \"degree\", \"label\": \"\", \"value\": \"{angle}\", \"variable\": \"Angle\"}}, \"State\": {{\"unit\": \"\", \"label\": \"\", \"value\": \"{state}\", \"variable\": \"State\"}}, \"Factor\": {{\"unit\": \"\", \"label\": \"\", \"value\": \"{factor}\", \"variable\": \"Factor\"}}, \"Current\": {{\"unit\": \"A\", \"label\": \"\", \"value\": \"{current}\", \"variable\": \"Current\"}}, \"Voltage\": {{\"unit\": \"V\", \"label\": \"\", \"value\": \"{voltage}\", \"variable\": \"Voltage\"}}, \"PowerActive\": {{\"unit\": \"W\", \"label\": \"\", \"value\": \"{poweractive}\", \"variable\": \"PowerActive\"}}, \"PowerApparent\": {{\"unit\": \"VA\", \"label\": \"\", \"value\": \"{powerapparent}\", \"variable\": \"PowerApparent\"}}, \"PowerReactive\": {{\"unit\": \"VA\", \"label\": \"\", \"value\": \"{powerreactive}\", \"variable\": \"PowerReactive\"}}, \"ExportEnergyActive\": {{\"unit\": \"Wh\", \"label\": \"\", \"value\": \"{exportenergyactive}\", \"variable\": \"ExportEnergyActive\"}}, \"ImportEnergyActive\": {{\"unit\": \"Wh\", \"label\": \"\", \"value\": \"{importenergyactive}\", \"variable\": \"ImportEnergyActive\"}}, \"PowerDemandReverse\": {{\"unit\": \"W\", \"label\": \"\", \"value\": \"{powerdemandreverse}\", \"variable\": \"PowerDemandReverse\"}}, \"PowerDemandPositive\": {{\"unit\": \"W\", \"label\": \"\", \"value\": \"{powerdemandpositive}\", \"variable\": \"PowerDemandPositive\"}}, \"ExportEnergyReactive\": {{\"unit\": \"VAh\", \"label\": \"\", \"value\": \"{exportenergyreactive}\", \"variable\": \"ExportEnergyReactive\"}}, \"ImportEnergyReactive\": {{\"unit\": \"VAh\", \"label\": \"\", \"value\": \"{importenergyreactive}\", \"variable\": \"ImportEnergyReactive\"}}}}"
|
||||
logger.info(f"{destTime=}, {destApplication=}, {destDevice=}, {destAttributes=}, {destValues=}")
|
||||
|
||||
|
||||
try:
|
||||
destCur.execute("insert into measurements (time, application, device, attributes, values) values(%s, %s, %s, %s, %s)",
|
||||
(destTime, destApplication, destDevice, destAttributes, destValues))
|
||||
destConn.commit()
|
||||
except Exception as e:
|
||||
destConn.rollback()
|
||||
logger.error(f"Error {e} when inserted time {destTime}")
|
||||
finally:
|
||||
if srcConn:
|
||||
srcConn.close()
|
||||
if destConn:
|
||||
destConn.close()
|
||||
|
||||
|
@ -1,78 +0,0 @@
|
||||
import psycopg2
|
||||
from loguru import logger
|
||||
import os
|
||||
|
||||
srcPgHost = os.environ["SRC_PGHOST"]
|
||||
srcPgUser = os.environ["SRC_PGUSER"]
|
||||
srcPgPassword = os.environ["SRC_PGPASSWORD"]
|
||||
srcPgDatabase = os.environ["SRC_PGDATABASE"]
|
||||
destPgHost = os.environ["DEST_PGHOST"]
|
||||
destPgUser = os.environ["DEST_PGUSER"]
|
||||
destPgPassword = os.environ["DEST_PGPASSWORD"]
|
||||
destPgDatabase = os.environ["DEST_PGDATABASE"]
|
||||
|
||||
try:
|
||||
srcConn = psycopg2.connect(
|
||||
host=srcPgHost,
|
||||
dbname=srcPgDatabase,
|
||||
user=srcPgUser,
|
||||
password=srcPgPassword,
|
||||
sslmode='require'
|
||||
)
|
||||
srcConn.autocommit = False
|
||||
|
||||
destConn = psycopg2.connect(
|
||||
host=destPgHost,
|
||||
dbname=destPgDatabase,
|
||||
user=destPgUser,
|
||||
password=destPgPassword,
|
||||
sslmode='require'
|
||||
)
|
||||
destConn.autocommit = False
|
||||
|
||||
with srcConn.cursor() as srcCur, destConn.cursor() as destCur:
|
||||
srcCur.execute("select time, location, status, temperature, category from room_climate_measurement_t where category = 'heating' and time > '2023-12-19 05:20:00' order by time")
|
||||
for srcObj in srcCur:
|
||||
timestamp = srcObj[0]
|
||||
location = srcObj[1]
|
||||
status = srcObj[2]
|
||||
temperature = srcObj[3]
|
||||
category = srcObj[4]
|
||||
|
||||
logger.info(f"{timestamp=}, {location=}, {status=}, {temperature=}, {category=}")
|
||||
|
||||
destTime = timestamp
|
||||
|
||||
match category:
|
||||
case 'heating':
|
||||
destApplication = 'Temperature Heating'
|
||||
case 'Outdoor':
|
||||
destApplication = 'Temperature Wago'
|
||||
case 'Device':
|
||||
destApplication = 'Temperature Wago'
|
||||
case 'Indoor':
|
||||
destApplication = 'Temperature Multisensor' if location != 'Anna-Koeln-2' else 'Temperature Shelly Plus HT'
|
||||
case 'Special':
|
||||
destApplication = 'Temperature Multisensor'
|
||||
|
||||
destDevice = location
|
||||
destAttributes = '{"ApplicationId":"temperature-imported", "Status":"' + status + '","Location":"' + location + '","Category":"' + category + '","Hint": "Migrated"}'
|
||||
destValues = '{"Value": {"unit": "°C", "label": "", "value": "' + str(temperature) + '", "variable": ""}}'
|
||||
|
||||
logger.info(f"{destTime=}, {destApplication=}, {destDevice=}, {destAttributes=}, {destValues=}")
|
||||
|
||||
try:
|
||||
destCur.execute("insert into measurements (time, application, device, attributes, values) values(%s, %s, %s, %s, %s)",
|
||||
(destTime, destApplication, destDevice, destAttributes, destValues))
|
||||
destConn.commit()
|
||||
except Exception as e:
|
||||
destConn.rollback()
|
||||
logger.error(f"Error {e} when inserted time {destTime}")
|
||||
|
||||
finally:
|
||||
if srcConn:
|
||||
srcConn.close()
|
||||
|
||||
if destConn:
|
||||
destConn.close()
|
||||
|
@ -1,2 +0,0 @@
|
||||
loguru==0.7.3
|
||||
psycopg2==2.9.9
|
Loading…
x
Reference in New Issue