Files
pv-controller/config/config.yaml
2025-12-03 19:03:46 +01:00

170 lines
5.6 KiB
YAML

mqtt:
broker: 172.16.2.16
port: 1883
publish_period: 15
modbus:
gateway: 172.16.2.42
# REGISTERS = [
# { "slave":2, "addr":0x0048, "type":"input", "attr": "importEnergyActive", "name":"Import active energy", "unit":"kWh", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x004c, "type":"input", "attr": "importEnergyReactive", "name":"Import reactive energy", "unit":"kVAh", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x004a, "type":"input", "attr": "exportEnergyActive", "name":"Export active energy", "unit":"kWh", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x004e, "type":"input", "attr": "exportEnergyReactive", "name":"Export reactive energy", "unit":"kVAh", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x0012, "type":"input", "attr": "powerApparent", "name":"Apparent Power", "unit":"W", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x000c, "type":"input", "attr": "powerActive", "name":"Active Power", "unit":"W", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x0018, "type":"input", "attr": "powerReactive", "name":"Reactive Power", "unit":"W", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x0058, "type":"input", "attr": "powerDemandPositive", "name":"PositivePowerDemand", "unit":"W", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x005c, "type":"input", "attr": "powerDemandReverse", "name":"ReversePowerDemand", "unit":"W", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x001e, "type":"input", "attr": "factor", "name":"Factor", "unit":"-", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x0024, "type":"input", "attr": "angle", "name":"Angle", "unit":"degree", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x0000, "type":"input", "attr": "voltage", "name":"Voltage", "unit":"V", "adaptor": floatAdaptor },
# { "slave":2, "addr":0x0006, "type":"input", "attr": "current", "name":"Current", "unit":"A", "adaptor": floatAdaptor },
# { "slave":1, "addr":0x0001, "type":"holding", "attr": "state", "name":"State", "unit":"-", "adaptor": onOffAdaptor },
# ]
output:
- name: pv_meter
publish_topic: IoT/PV/Values
slave_id: 2
registers:
- address: 0x0048
attribute: importEnergyActive
name: Import active energy
unit: kWh
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x004c
attribute: importEnergyReactive
name: Import reactive energy
unit: kVAh
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x004a
attribute: exportEnergyActive
name: Export active energy
unit: kWh
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x004e
attribute: exportEnergyReactive
name: Export reactive energy
unit: kVAh
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x0012
attribute: powerApparent
name: Apparent Power
unit: W
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x000c
attribute: powerActive
name: Active Power
unit: W
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x0018
attribute: powerReactive
name: Reactive Power
unit: W
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x0058
attribute: powerDemandPositive
name: PositivePowerDemand
unit: W
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x005c
attribute: powerDemandReverse
name: ReversePowerDemand
unit: W
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x001e
attribute: factor
name: Factor
unit: "-"
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x0024
attribute: angle
name: Angle
unit: degree
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x0000
attribute: voltage
name: Voltage
unit: V
register_type: input
data_type: float32
adaptor: floatAdaptor
- address: 0x0006
attribute: current
name: Current
unit: A
register_type: input
data_type: float32
adaptor: floatAdaptor
- name: pv_control
publish_topic: IoT/PV/Control
slave_id: 1
registers:
- address: 0x0001
attribute: state
name: State
unit: "-"
register_type: holding
data_type: int32
adaptor: onOffAdaptor
- name: car_control
publish_topic: IoT/Car/Control
slave_id: 5
registers:
- address: 0x0001
attribute: state
name: State
unit: "-"
register_type: holding
data_type: int32
adaptor: onOffAdaptor
- name: car_meter
enabled: true
publish_topic: IoT/Car/Values
slave_id: 6
registers:
- address: 14
attribute: voltageL1
name: Voltage L1
unit: V
register_type: holding
data_type: float32
adaptor: floatAdaptor
- address: 16
attribute: voltageL2
name: Voltage L2
unit: V
register_type: holding
data_type: float32
adaptor: floatAdaptor
- address: 18
attribute: voltageL3
name: Voltage L3
unit: V
register_type: holding
data_type: float32
adaptor: floatAdaptor