changes working so far
This commit is contained in:
@@ -1,10 +1,10 @@
|
||||
mqtt:
|
||||
broker: ${MQTT__BROKER}
|
||||
port: ${MQTT__PORT}
|
||||
broker: 172.16.2.16
|
||||
port: 1883
|
||||
publish_period: 15
|
||||
|
||||
modbus:
|
||||
gateway: ${MODBUS__GATEWAY}
|
||||
|
||||
gateway: 172.16.2.42
|
||||
|
||||
# REGISTERS = [
|
||||
# { "slave":2, "addr":0x0048, "type":"input", "attr": "importEnergyActive", "name":"Import active energy", "unit":"kWh", "adaptor": floatAdaptor },
|
||||
@@ -26,7 +26,6 @@ modbus:
|
||||
output:
|
||||
- name: pv_meter
|
||||
publish_topic: IoT/PV/Values
|
||||
publish_period: 15
|
||||
slave_id: 2
|
||||
registers:
|
||||
- address: 0x0048
|
||||
@@ -34,95 +33,94 @@ output:
|
||||
name: Import active energy
|
||||
unit: kWh
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x004c
|
||||
attribute: importEnergyReactive
|
||||
name: Import reactive energy
|
||||
unit: kVAh
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x004a
|
||||
attribute: exportEnergyActive
|
||||
name: Export active energy
|
||||
unit: kWh
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x004e
|
||||
attribute: exportEnergyReactive
|
||||
name: Export reactive energy
|
||||
unit: kVAh
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x0012
|
||||
attribute: powerApparent
|
||||
name: Apparent Power
|
||||
unit: W
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x000c
|
||||
attribute: powerActive
|
||||
name: Active Power
|
||||
unit: W
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x0018
|
||||
attribute: powerReactive
|
||||
name: Reactive Power
|
||||
unit: W
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x0058
|
||||
attribute: powerDemandPositive
|
||||
name: PositivePowerDemand
|
||||
unit: W
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x005c
|
||||
attribute: powerDemandReverse
|
||||
name: ReversePowerDemand
|
||||
unit: W
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x001e
|
||||
attribute: factor
|
||||
name: Factor
|
||||
unit: "-"
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x0024
|
||||
attribute: angle
|
||||
name: Angle
|
||||
unit: degree
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x0000
|
||||
attribute: voltage
|
||||
name: Voltage
|
||||
unit: V
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- address: 0x0006
|
||||
attribute: current
|
||||
name: Current
|
||||
unit: A
|
||||
register_type: input
|
||||
data_type: float
|
||||
data_type: float32
|
||||
adaptor: floatAdaptor
|
||||
- name: pv_control
|
||||
publish_topic: IoT/PV/Control
|
||||
publish_period: 15
|
||||
slave_id: 1
|
||||
registers:
|
||||
- address: 0x0001
|
||||
@@ -130,5 +128,5 @@ output:
|
||||
name: State
|
||||
unit: "-"
|
||||
register_type: holding
|
||||
data_type: int
|
||||
adaptor: onOffAdaptor
|
||||
data_type: int32
|
||||
adaptor: onOffAdaptor
|
||||
Reference in New Issue