<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>44493951</Id>
<Manufacturer>ELS</Manufacturer>
<Version>47</Version>
<ProductName>Elster F96 Plus</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>161</AccessNumber>
<Status>70</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>DDDDEBBD</Value>
</DataRecord>
<DataRecord id="5">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>DDEBBD</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>227</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>226</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (1e-1 deg C)</Unit>
<Value>1</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Operating time (days)</Unit>
<Value>730</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T13:09:00</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2013-05-31</Value>
</DataRecord>
</MBusData>