<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>66660205</Id>
<Manufacturer>LUG</Manufacturer>
<Version>7</Version>
<ProductName>Landis &amp; Gyr Ultraheat T230</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>1</AccessNumber>
<Status>10</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>s</Unit>
<Quantity>Averaging Duration</Quantity>
<Value>4.000000</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>s</Unit>
<Quantity>Averaging Duration</Quantity>
<Value>8.000000</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m^3</Unit>
<Quantity>Volume</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>W</Unit>
<Quantity>Power</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m^3/h</Unit>
<Quantity>Volume flow</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>°C</Unit>
<Quantity>Flow temperature</Quantity>
<Value>19.500000</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>°C</Unit>
<Quantity>Return temperature</Quantity>
<Value>19.700000</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>K</Unit>
<Quantity>Temperature difference</Quantity>
<Value>-0.200000</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit></Unit>
<Quantity>Fabrication No</Quantity>
<Value>66660205.000000</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>s</Unit>
<Quantity>Averaging Duration</Quantity>
<Value>420.000000</Value>
</DataRecord>
<DataRecord id="11">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>s</Unit>
<Quantity>On time</Quantity>
<Value>13568400.000000</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>s</Unit>
<Quantity>On time</Quantity>
<Value>13568400.000000</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>s</Unit>
<Quantity>Operating time</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>5</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="15">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>W</Unit>
<Quantity>Power</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="16">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>m^3/h</Unit>
<Quantity>Volume flow</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="17">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>°C</Unit>
<Quantity>Flow temperature</Quantity>
<Value>30.700000</Value>
</DataRecord>
<DataRecord id="18">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>°C</Unit>
<Quantity>Return temperature</Quantity>
<Value>50.700000</Value>
</DataRecord>
<DataRecord id="19">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>W</Unit>
<Quantity>Power</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="20">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>m^3/h</Unit>
<Quantity>Volume flow</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="21">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>°C</Unit>
<Quantity>Flow temperature</Quantity>
<Value>41065374.600000</Value>
</DataRecord>
<DataRecord id="22">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>°C</Unit>
<Quantity>Return temperature</Quantity>
<Value>40953732.300000</Value>
</DataRecord>
<DataRecord id="23">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="24">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>m^3</Unit>
<Quantity>Volume</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="25">
<Function>Value during error state</Function>
<StorageNumber>1</StorageNumber>
<Unit>s</Unit>
<Quantity>On time</Quantity>
<Value>12488400.000000</Value>
</DataRecord>
<DataRecord id="26">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>s</Unit>
<Quantity>Operating time</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="27">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>5</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="28">
<Function>Maximum value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>W</Unit>
<Quantity>Power</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="29">
<Function>Maximum value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>m^3/h</Unit>
<Quantity>Volume flow</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="30">
<Function>Maximum value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>°C</Unit>
<Quantity>Flow temperature</Quantity>
<Value>30.700000</Value>
</DataRecord>
<DataRecord id="31">
<Function>Maximum value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>°C</Unit>
<Quantity>Return temperature</Quantity>
<Value>50.700000</Value>
</DataRecord>
<DataRecord id="32">
<Function>Instantaneous value</Function>
<StorageNumber>510</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>-</Unit>
<Quantity>Time point (date &amp; time)</Quantity>
<Value>2127-01-01T00:00:00Z</Value>
</DataRecord>
<DataRecord id="33">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>-</Unit>
<Quantity>Time point (date &amp; time)</Quantity>
<Value>2012-01-13T12:04:00Z</Value>
</DataRecord>
<DataRecord id="34">
<Function>Manufacturer specific</Function>
<StorageNumber>0</StorageNumber>
<Unit></Unit>
<Quantity></Quantity>
<Value>09 07 00 66 01</Value>
</DataRecord>
</MBusData>