libmbus/test/test-frames/engelmann_sensostar2c.norm.xml
2020-07-06 12:55:05 +02:00

226 lines
6.3 KiB
XML

<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>10380010</Id>
<Manufacturer>EFE</Manufacturer>
<Version>1</Version>
<ProductName>Engelmann SensoStar 2C</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>30</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit></Unit>
<Quantity>Fabrication No</Quantity>
<Value>10380010.000000</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>-</Unit>
<Quantity>Time point (date &amp; time)</Quantity>
<Value>2012-06-06T20:50:00Z</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m^3</Unit>
<Quantity>Volume</Quantity>
<Value>12.900000</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>800000.000000</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>3</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m^3/h</Unit>
<Quantity>Volume flow</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>W</Unit>
<Quantity>Power</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>°C</Unit>
<Quantity>Flow temperature</Quantity>
<Value>95.000000</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>°C</Unit>
<Quantity>Return temperature</Quantity>
<Value>43.000000</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>K</Unit>
<Quantity>Temperature difference</Quantity>
<Value>52.580000</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>s</Unit>
<Quantity>Operating time</Quantity>
<Value>43718400.000000</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit></Unit>
<Quantity>Error flags</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m^3</Unit>
<Quantity>Volume</Quantity>
<Value>0.100000</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>-</Unit>
<Quantity>Time point (date)</Quantity>
<Value>2011-12-31</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>m^3</Unit>
<Quantity>Volume</Quantity>
<Value>12.900000</Value>
</DataRecord>
<DataRecord id="16">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>800000.000000</Value>
</DataRecord>
<DataRecord id="17">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="18">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>3</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="19">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>-</Unit>
<Quantity>Time point (date)</Quantity>
<Value>2010-12-31</Value>
</DataRecord>
<DataRecord id="20">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>m^3</Unit>
<Quantity>Volume</Quantity>
<Value>8.400000</Value>
</DataRecord>
<DataRecord id="21">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>500000.000000</Value>
</DataRecord>
<DataRecord id="22">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="23">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>3</Tariff>
<Device>0</Device>
<Unit>Wh</Unit>
<Quantity>Energy</Quantity>
<Value>0.000000</Value>
</DataRecord>
</MBusData>