New test frame for Elvaco temperature / humidity meter (from Jakob

Skov-Pedersen)
This commit is contained in:
Stefan Wahren 2012-10-21 10:55:48 +02:00
parent 3de91c5eab
commit cf297a56c3
2 changed files with 105 additions and 0 deletions

View File

@ -0,0 +1 @@
68 53 53 68 08 05 72 34 08 00 54 96 15 32 00 F2 00 00 00 01 FD 1B 00 02 FC 03 48 52 25 74 D4 11 22 FC 03 48 52 25 74 C8 11 12 FC 03 48 52 25 74 B4 16 02 65 D0 08 22 65 70 08 12 65 23 09 01 72 18 42 65 E4 08 82 01 65 DD 08 0C 78 34 08 00 54 03 FD 0F 00 00 04 1F 5D 16

View File

@ -0,0 +1,104 @@
<MBusData>
<SlaveInformation>
<Id>54000834</Id>
<Manufacturer>ELV</Manufacturer>
<Version>50</Version>
<ProductName></ProductName>
<Medium>Other</Medium>
<AccessNumber>242</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<Unit>Digital input (binary)</Unit>
<Value>0</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<Unit>1e-2 %RH</Unit>
<Value>4564</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="2">
<Function>Minimum value</Function>
<Unit>1e-2 %RH</Unit>
<Value>4552</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="3">
<Function>Maximum value</Function>
<Unit>1e-2 %RH</Unit>
<Value>5812</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2256</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="5">
<Function>Minimum value</Function>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2160</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="6">
<Function>Maximum value</Function>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2339</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<Unit>Averaging Duration (hours)</Unit>
<Value>24</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2276</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2269</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<Unit>Fabrication number</Unit>
<Value>54000834</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<Unit>Software version</Unit>
<Value>262144</Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
<DataRecord id="12">
<Function>More records follow</Function>
<Value></Value>
<Timestamp>1970-01-01T00:00:00</Timestamp>
</DataRecord>
</MBusData>