@ -955,14 +955,21 @@ mbus_data_product_name(mbus_data_variable_header *header)
}
else if (manufacturer == mbus_manufacturer_id("AMT"))
{
switch (header->version)
if (header->version >= 0xC0)
{
case 0x80:
strcpy(buff,"Aquametro CALEC MB");
break;
case 0xC0:
strcpy(buff,"Aquametro CALEC ST");
break;
strcpy(buff,"Aquametro CALEC ST");
}
else if (header->version >= 0x80)
{
strcpy(buff,"Aquametro CALEC MB");
}
else if (header->version >= 0x40)
{
strcpy(buff,"Aquametro SAPHIR");
}
else
{
strcpy(buff,"Aquametro AMTRON");
}
}
else if (manufacturer == mbus_manufacturer_id("BEC"))
@ -1266,15 +1273,16 @@ mbus_data_product_name(mbus_data_variable_header *header)
{
switch (header->version)
{
case 0x08:
case 0x19:
strcpy(buff,"Sensus PolluCom E");
break;
case 0x0B:
strcpy(buff,"Sensus PolluTherm");
break;
case 0x0E:
strcpy(buff,"Sensus PolluStat E");
break;
case 0x19:
strcpy(buff,"Sensus PolluCom E");
break;
}
}