Merge pull request from arska/feature-ignoretestbinaries

Thanks a lot
This commit is contained in:
Stefan Wahren 2016-03-26 11:43:42 +01:00
commit 78298bc68e
65 changed files with 2398 additions and 90 deletions

7
.gitignore vendored

@ -62,3 +62,10 @@ bin/mbus-tcp-select-secondary
bin/mbus-tcp-application-reset
!*.c
# test binaries
test/mbus_parse
test/mbus_parse_hex
# test cases temp files
test/test-frames/*.xml.new

@ -857,6 +857,8 @@ mbus_data_product_name(mbus_data_variable_header *header)
{
manufacturer = (header->manufacturer[1] << 8) + header->manufacturer[0];
// please keep this list ordered by manufacturer code
if (manufacturer == mbus_manufacturer_id("ABB"))
{
switch (header->version)
@ -942,6 +944,9 @@ mbus_data_product_name(mbus_data_variable_header *header)
{
switch (header->version)
{
case 0x02:
strcpy(buff,"Elster TMP-A");
break;
case 0x0A:
strcpy(buff,"Elster Falcon");
break;
@ -980,6 +985,15 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("EMH"))
{
switch (header->version)
{
case 0x00:
strcpy(buff,"EMH DIZ");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("EMU"))
{
if (header->medium == MBUS_VARIABLE_DATA_MEDIUM_ELECTRICITY)
@ -1023,6 +1037,18 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("KAM"))
{
switch (header->version)
{
case 0x01:
strcpy(buff,"Kamstrup 382 (6850-005)");
break;
case 0x08:
strcpy(buff,"Kamstrup Multical 601");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("SLB"))
{
switch (header->version)
@ -1074,6 +1100,27 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("LSE"))
{
switch (header->version)
{
case 0x99:
strcpy(buff,"Siemens WFH21");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("NZR"))
{
switch (header->version)
{
case 0x01:
strcpy(buff,"NZR DHZ 5/63");
break;
case 0x50:
strcpy(buff,"NZR IC-M2");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("RAM"))
{
switch (header->version)
@ -1113,33 +1160,16 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("SVM"))
else if (manufacturer == mbus_manufacturer_id("SBC"))
{
switch (header->version)
switch (header->id_bcd[3])
{
case 0x08:
strcpy(buff,"Elster F2 / Deltamess F2");
case 0x10:
case 0x19:
strcpy(buff,"Saia-Burgess ALE3");
break;
case 0x09:
strcpy(buff,"Elster F4 / Kamstrup SVM F22");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("SON"))
{
switch (header->version)
{
case 0x0D:
strcpy(buff,"Sontex Supercal 531");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("LSE"))
{
switch (header->version)
{
case 0x99:
strcpy(buff,"Siemens WFH21");
case 0x11:
strcpy(buff,"Saia-Burgess AWD3");
break;
}
}
@ -1158,6 +1188,15 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("SON"))
{
switch (header->version)
{
case 0x0D:
strcpy(buff,"Sontex Supercal 531");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("SPX"))
{
switch (header->version)
@ -1168,46 +1207,15 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("ELS"))
else if (manufacturer == mbus_manufacturer_id("SVM"))
{
switch (header->version)
{
case 0x02:
strcpy(buff,"Elster TMP-A");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("NZR"))
{
switch (header->version)
{
case 0x01:
strcpy(buff,"NZR DHZ 5/63");
break;
case 0x50:
strcpy(buff,"NZR IC-M2");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("KAM"))
{
switch (header->version)
{
case 0x01:
strcpy(buff,"Kamstrup 382 (6850-005)");
break;
case 0x08:
strcpy(buff,"Kamstrup Multical 601");
strcpy(buff,"Elster F2 / Deltamess F2");
break;
}
}
else if (manufacturer == mbus_manufacturer_id("EMH"))
{
switch (header->version)
{
case 0x00:
strcpy(buff,"EMH DIZ");
case 0x09:
strcpy(buff,"Elster F4 / Kamstrup SVM F22");
break;
}
}
@ -1232,19 +1240,6 @@ mbus_data_product_name(mbus_data_variable_header *header)
break;
}
}
else if (manufacturer == mbus_manufacturer_id("SBC"))
{
switch (header->id_bcd[3])
{
case 0x10:
case 0x19:
strcpy(buff,"Saia-Burgess ALE3");
break;
case 0x11:
strcpy(buff,"Saia-Burgess AWD3");
break;
}
}
}

0
test/test-frames/ACW_Itron-BM-plus-m.hex Executable file → Normal file

@ -0,0 +1,76 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>11490378</Id>
<Manufacturer>ACW</Manufacturer>
<Version>14</Version>
<ProductName>Itron BM +m</ProductName>
<Medium>Cold water</Medium>
<AccessNumber>10</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>11490378</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>54321</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2000-00-00</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T11:11:00</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Operating time (days)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Firmware version</Unit>
<Value>2</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Software version</Unit>
<Value>6</Value>
</DataRecord>
<DataRecord id="8">
<Function>Manufacturer specific</Function>
<Value>00 01 75 13</Value>
</DataRecord>
</MBusData>

0
test/test-frames/ACW_Itron-CYBLE-M-Bus-14.hex Executable file → Normal file

@ -0,0 +1,69 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>9011523</Id>
<Manufacturer>ACW</Manufacturer>
<Version>20</Version>
<ProductName>Itron CYBLE M-Bus 1.4</ProductName>
<Medium>Water</Medium>
<AccessNumber>37</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>9011523</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>cust. ID</Unit>
<Value>09LA076755</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T14:26:00</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>bat. time</Unit>
<Value>2516</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>31</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>31</Value>
</DataRecord>
<DataRecord id="7">
<Function>Manufacturer specific</Function>
<Value>00 01 1F</Value>
</DataRecord>
</MBusData>

207
test/test-frames/EDC.xml Normal file

@ -0,0 +1,207 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>11120895</Id>
<Manufacturer>EDC</Manufacturer>
<Version>2</Version>
<ProductName></ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>23</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>35</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>465</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Flow temperature (deg C)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Return temperature (deg C)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Flow temperature (deg C)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Return temperature (deg C)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>-0.000000</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="10">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>-0.000000</Value>
</DataRecord>
<DataRecord id="11">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Power (W)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (W)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="14">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Power (W)</Unit>
<Value>-1370640613376.000000</Value>
</DataRecord>
<DataRecord id="15">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (W)</Unit>
<Value>0.000000</Value>
</DataRecord>
<DataRecord id="16">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2012-07-10T15:25:00</Value>
</DataRecord>
<DataRecord id="17">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>C</Unit>
<Value>3571</Value>
</DataRecord>
<DataRecord id="18">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>C</Unit>
<Value>413</Value>
</DataRecord>
<DataRecord id="19">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>c</Unit>
<Value>1</Value>
</DataRecord>
<DataRecord id="20">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>c</Unit>
<Value>1</Value>
</DataRecord>
<DataRecord id="21">
<Function>Manufacturer specific</Function>
<Value></Value>
</DataRecord>
</MBusData>

0
test/test-frames/EFE_Engelmann-Elster-SensoStar-2.hex Executable file → Normal file

@ -0,0 +1,204 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>24083345</Id>
<Manufacturer>EFE</Manufacturer>
<Version>0</Version>
<ProductName>Engelmann / Elster SensoStar 2</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>102</AccessNumber>
<Status>27</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>24083345</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-12T14:23:00</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (1e-1 m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (1e-1 m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Volume (1e-1 m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2013-12-31</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2014-12-31</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>3</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="16">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>25</Value>
</DataRecord>
<DataRecord id="17">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="18">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>11</Value>
</DataRecord>
<DataRecord id="19">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (deg C)</Unit>
<Value>22</Value>
</DataRecord>
<DataRecord id="20">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (deg C)</Unit>
<Value>21</Value>
</DataRecord>
<DataRecord id="21">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (1e-2 deg C)</Unit>
<Value>9</Value>
</DataRecord>
<DataRecord id="22">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>On time (days)</Unit>
<Value>524</Value>
</DataRecord>
<DataRecord id="23">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Error flags</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="24">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (my m^3)</Unit>
<Value>11</Value>
</DataRecord>
</MBusData>

0
test/test-frames/EFE_Engelmann-WaterStar.hex Executable file → Normal file

@ -0,0 +1,101 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>4990254</Id>
<Manufacturer>EFE</Manufacturer>
<Version>0</Version>
<ProductName>Engelmann WaterStar</ProductName>
<Medium>Hot water</Medium>
<AccessNumber>12</AccessNumber>
<Status>27</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>4990254</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T12:10:00</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>332</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>331</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Volume (m m^3)</Unit>
<Value>332</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2013-12-31</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2014-12-31</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="8">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>2070</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>On time (days)</Unit>
<Value>1191</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Error flags</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (my m^3)</Unit>
<Value>8</Value>
</DataRecord>
</MBusData>

0
test/test-frames/ELS_Elster-F96-Plus.hex Executable file → Normal file

@ -0,0 +1,135 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>44493951</Id>
<Manufacturer>ELS</Manufacturer>
<Version>47</Version>
<ProductName>Elster F96 Plus</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>161</AccessNumber>
<Status>70</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>144445223</Value>
</DataRecord>
<DataRecord id="5">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>1445223</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>227</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>226</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (1e-1 deg C)</Unit>
<Value>1</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Operating time (days)</Unit>
<Value>730</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T13:09:00</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2013-05-31</Value>
</DataRecord>
</MBusData>

@ -0,0 +1 @@
68 53 53 68 08 0B 72 61 15 01 24 96 15 16 00 3F 00 00 00 01 FD 1B 02 02 FC 03 48 52 25 74 22 15 22 FC 03 48 52 25 74 24 0D 12 FC 03 48 52 25 74 C3 1C 02 65 2E 08 22 65 5C 05 12 65 A2 0B 01 72 18 42 65 2C 08 82 01 65 1F 08 0C 78 61 15 01 24 03 FD 0F 00 00 04 1F BD 16

@ -0,0 +1,106 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>24011561</Id>
<Manufacturer>ELV</Manufacturer>
<Version>22</Version>
<ProductName>Elvaco CMa10</ProductName>
<Medium>Other</Medium>
<AccessNumber>63</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Digital input (binary)</Unit>
<Value>2</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-2 %RH</Unit>
<Value>5410</Value>
</DataRecord>
<DataRecord id="2">
<Function>Minimum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-2 %RH</Unit>
<Value>3364</Value>
</DataRecord>
<DataRecord id="3">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-2 %RH</Unit>
<Value>7363</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2094</Value>
</DataRecord>
<DataRecord id="5">
<Function>Minimum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>1372</Value>
</DataRecord>
<DataRecord id="6">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2978</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Averaging Duration (hours)</Unit>
<Value>24</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2092</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>External temperature (1e-2 deg C)</Unit>
<Value>2079</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>24011561</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Software version</Unit>
<Value>262144</Value>
</DataRecord>
<DataRecord id="12">
<Function>More records follow</Function>
<Value></Value>
</DataRecord>
</MBusData>

0
test/test-frames/EMU_EMU-Professional-375-M-Bus.hex Executable file → Normal file

@ -0,0 +1,255 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>32629</Id>
<Manufacturer>EMU</Manufacturer>
<Version>16</Version>
<ProductName>EMU Professional 3/75 M-Bus</ProductName>
<Medium>Electricity</Medium>
<AccessNumber>2</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>32629</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (Wh)</Unit>
<Value>1364</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Energy (Wh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>2</Device>
<Unit>Energy (Wh)</Unit>
<Value>7854</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>2</Device>
<Unit>Energy (Wh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>-2</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>-2</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>2</Device>
<Unit>Power (W)</Unit>
<Value>14</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>2</Device>
<Unit>Power (W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>2</Device>
<Unit>Power (W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>2</Device>
<Unit>Power (W)</Unit>
<Value>14</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>2257</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="16">
<Function>Minimum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>1874</Value>
</DataRecord>
<DataRecord id="17">
<Function>Minimum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="18">
<Function>Minimum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="19">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>2410</Value>
</DataRecord>
<DataRecord id="20">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="21">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="22">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m A</Unit>
<Value>-66</Value>
</DataRecord>
<DataRecord id="23">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m A</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="24">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m A</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="25">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>m A</Unit>
<Value>-66</Value>
</DataRecord>
<DataRecord id="26">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Manufacturer specific</Unit>
<Value>13</Value>
</DataRecord>
<DataRecord id="27">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Manufacturer specific</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="28">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Manufacturer specific</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="29">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Manufacturer specific</Unit>
<Value>500</Value>
</DataRecord>
<DataRecord id="30">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Unrecognized VIF extension: 0x60</Unit>
<Value>56</Value>
</DataRecord>
<DataRecord id="31">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Error flags</Unit>
<Value>0</Value>
</DataRecord>
</MBusData>

@ -1,10 +1,11 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>802657</Id>
<Manufacturer>SVM</Manufacturer>
<Version>8</Version>
<ProductName>Elster F2</ProductName>
<ProductName>Elster F2 / Deltamess F2</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>70</AccessNumber>
<Status>00</Status>

@ -0,0 +1 @@
68 38 38 68 08 19 72 07 62 00 23 2E 19 23 02 92 00 00 00 8C 10 04 68 28 17 00 8C 11 04 68 28 17 00 02 FD C9 FF 01 E6 00 02 FD DB FF 01 06 00 02 AC FF 01 09 00 82 40 AC FF 01 FD FF 5B 16

@ -0,0 +1,63 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>23006207</Id>
<Manufacturer>FIN</Manufacturer>
<Version>35</Version>
<ProductName></ProductName>
<Medium>Electricity</Medium>
<AccessNumber>146</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>172868</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>172868</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit> V</Unit>
<Value>230</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 A</Unit>
<Value>6</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>9</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (10 W)</Unit>
<Value>-3</Value>
</DataRecord>
</MBusData>

@ -0,0 +1 @@
68 1B 1B 68 08 01 72 07 20 18 00 E6 1E 35 07 4C 00 00 00 0C 78 07 20 18 00 0C 16 69 02 00 00 96 16

@ -0,0 +1,29 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>182007</Id>
<Manufacturer>GWF</Manufacturer>
<Version>53</Version>
<ProductName></ProductName>
<Medium>Water</Medium>
<AccessNumber>76</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>182007</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume ( m^3)</Unit>
<Value>269</Value>
</DataRecord>
</MBusData>

@ -0,0 +1 @@
68 2F 2F 68 08 16 72 01 63 21 11 AC 48 41 03 B1 00 00 00 0C 14 81 60 87 02 04 6D A1 15 E9 17 42 6C DF 1C 4C 14 82 73 59 02 42 EC 7E FF 1C 0F C0 01 01 0C BD 16

@ -0,0 +1,55 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>11216301</Id>
<Manufacturer>REL</Manufacturer>
<Version>65</Version>
<ProductName></ProductName>
<Medium>Gas</Medium>
<AccessNumber>177</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>2876081</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2000-01-00T00:00:00</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2014-12-31</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>2597382</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2015-12-31</Value>
</DataRecord>
<DataRecord id="5">
<Function>Manufacturer specific</Function>
<Value>C0 01 01 0C</Value>
</DataRecord>
</MBusData>

0
test/test-frames/SBC_Saia-Burgess-ALE3.hex Executable file → Normal file

@ -0,0 +1,171 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>19000055</Id>
<Manufacturer>SBC</Manufacturer>
<Version>22</Version>
<ProductName>Saia-Burgess ALE3</ProductName>
<Medium>Electricity</Medium>
<AccessNumber>191</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>293</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>1</Tariff>
<Device>0</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>293</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>6</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>2</Tariff>
<Device>0</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>6</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit> V</Unit>
<Value>223</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 A</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit> V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 A</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit> V</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>1e-1 A</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="16">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Manufacturer specific</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="17">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="18">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="19">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Manufacturer specific</Unit>
<Value>0</Value>
</DataRecord>
</MBusData>

0
test/test-frames/SEN_Sensus-PolluStat-E.hex Executable file → Normal file

@ -0,0 +1,83 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>21265095</Id>
<Manufacturer>SEN</Manufacturer>
<Version>14</Version>
<ProductName>Sensus PolluStat E</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>181</AccessNumber>
<Status>10</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>201</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>202</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (m deg C)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>21265095</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Customer location</Unit>
<Value>21265095</Value>
</DataRecord>
<DataRecord id="9">
<Function>More records follow</Function>
<Value></Value>
</DataRecord>
</MBusData>

0
test/test-frames/SEN_Sensus-PolluTherm.hex Executable file → Normal file

@ -0,0 +1,78 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>24351689</Id>
<Manufacturer>SEN</Manufacturer>
<Version>11</Version>
<ProductName>Sensus PolluTherm</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>84</AccessNumber>
<Status>10</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (10 kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (1e-2 m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="5">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="6">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (m deg C)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>24351689</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Customer location</Unit>
<Value>24351689</Value>
</DataRecord>
</MBusData>

0
test/test-frames/SLB_CF-Compact-Integral-MK-MaXX.hex Executable file → Normal file

@ -0,0 +1,122 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>11817314</Id>
<Manufacturer>SLB</Manufacturer>
<Version>6</Version>
<ProductName>CF Compact / Integral MK MaXX</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>3</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>11817314</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>2</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>218</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>220</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (1e-2 deg C)</Unit>
<Value>1500018</Value>
</DataRecord>
<DataRecord id="7">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Operating time (hours)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Operating time (days)</Unit>
<Value>1176</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T14:02:00</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>123</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>2</Device>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>321</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Firmware version</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Software version</Unit>
<Value>18</Value>
</DataRecord>
<DataRecord id="14">
<Function>Manufacturer specific</Function>
<Value>00 16</Value>
</DataRecord>
</MBusData>

0
test/test-frames/ZRM_Minol-Minocal-C2.hex Executable file → Normal file

@ -0,0 +1,301 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>31425084</Id>
<Manufacturer>ZRM</Manufacturer>
<Version>129</Version>
<ProductName>Minol Minocal C2</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>115</AccessNumber>
<Status>27</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Error flags</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>8</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2015-01-01T00:00:00</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>8</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>10</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>74</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Maximum value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>43</Value>
</DataRecord>
<DataRecord id="8">
<Function>Maximum value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2011-09-01T08:30:00</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (100 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="10">
<Function>Maximum value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Power (100 W)</Unit>
<Value>20</Value>
</DataRecord>
<DataRecord id="11">
<Function>Maximum value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2011-09-01T08:30:00</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-2 deg C)</Unit>
<Value>2071</Value>
</DataRecord>
<DataRecord id="13">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-2 deg C)</Unit>
<Value>2038</Value>
</DataRecord>
<DataRecord id="14">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2014-03-13T12:45:00</Value>
</DataRecord>
<DataRecord id="15">
<Function>Instantaneous value</Function>
<StorageNumber>32</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2014-03-01</Value>
</DataRecord>
<DataRecord id="16">
<Function>Instantaneous value</Function>
<StorageNumber>32</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="17">
<Function>Instantaneous value</Function>
<StorageNumber>33</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2014-02-01</Value>
</DataRecord>
<DataRecord id="18">
<Function>Instantaneous value</Function>
<StorageNumber>33</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="19">
<Function>Instantaneous value</Function>
<StorageNumber>34</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2014-01-01</Value>
</DataRecord>
<DataRecord id="20">
<Function>Instantaneous value</Function>
<StorageNumber>34</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="21">
<Function>Instantaneous value</Function>
<StorageNumber>35</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2013-12-01</Value>
</DataRecord>
<DataRecord id="22">
<Function>Instantaneous value</Function>
<StorageNumber>35</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="23">
<Function>Instantaneous value</Function>
<StorageNumber>36</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2013-11-01</Value>
</DataRecord>
<DataRecord id="24">
<Function>Instantaneous value</Function>
<StorageNumber>36</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="25">
<Function>Instantaneous value</Function>
<StorageNumber>37</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2013-10-01</Value>
</DataRecord>
<DataRecord id="26">
<Function>Instantaneous value</Function>
<StorageNumber>37</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="27">
<Function>Instantaneous value</Function>
<StorageNumber>38</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2013-09-01</Value>
</DataRecord>
<DataRecord id="28">
<Function>Instantaneous value</Function>
<StorageNumber>38</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="29">
<Function>Instantaneous value</Function>
<StorageNumber>39</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2013-08-01</Value>
</DataRecord>
<DataRecord id="30">
<Function>Instantaneous value</Function>
<StorageNumber>39</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (kWh)</Unit>
<Value>3</Value>
</DataRecord>
<DataRecord id="31">
<Function>Maximum value</Function>
<StorageNumber>32</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (date)</Unit>
<Value>2014-03-01</Value>
</DataRecord>
<DataRecord id="32">
<Function>Maximum value</Function>
<StorageNumber>32</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="33">
<Function>Maximum value</Function>
<StorageNumber>32</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Power (100 W)</Unit>
<Value>0</Value>
</DataRecord>
</MBusData>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
@ -13,78 +14,95 @@
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (100 Wh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (1e-4 m^3)</Unit>
<Value>742</Value>
</DataRecord>
<DataRecord id="2">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (1e-1 W)</Unit>
<Value>144521543</Value>
</DataRecord>
<DataRecord id="3">
<Function>Value during error state</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (1e-4 m^3/h)</Unit>
<Value>1521543</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>204</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>204</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (1e-1 deg C)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2012-01-13T16:34:00</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Energy (100 Wh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2011-04-30T23:59:00</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2012-04-30T23:59:00</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Energy (100 Wh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>2</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2011-12-31T23:59:00</Value>
</DataRecord>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -0,0 +1,76 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>70112345</Id>
<Manufacturer>ELS</Manufacturer>
<Version>10</Version>
<ProductName></ProductName>
<Medium>Water</Medium>
<AccessNumber>2</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>1234567</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2007-02-06T13:58:00</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2007-01-01</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>456951</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2008-01-01</Value>
</DataRecord>
<DataRecord id="5">
<Function>Maximum value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>5945</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2008-01-01</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>6137</Value>
</DataRecord>
<DataRecord id="8">
<Function>Manufacturer specific</Function>
<Value>0E 42 20 01 01 01 00 05 08 5E 01 20 3D 12 08 3D 12 08 00</Value>
</DataRecord>
</MBusData>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
@ -13,18 +14,25 @@
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>12565</Value>
</DataRecord>
<DataRecord id="1">
<Function>Maximum value</Function>
<StorageNumber>5</StorageNumber>
<Tariff>0</Tariff>
<Device>0</Device>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>113</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>2</Tariff>
<Device>1</Device>
<Unit>Energy (10 Wh)</Unit>
<Value>21837</Value>
</DataRecord>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>

@ -0,0 +1,55 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>4</Id>
<Manufacturer>REL</Manufacturer>
<Version>18</Version>
<ProductName></ProductName>
<Medium>Other</Medium>
<AccessNumber>1</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (mWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2001-09-20T13:16:00</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2000-12-31</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Energy (mWh)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2001-12-31</Value>
</DataRecord>
<DataRecord id="5">
<Function>Manufacturer specific</Function>
<Value>43 01 01 00</Value>
</DataRecord>
</MBusData>

@ -0,0 +1,55 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>1030101</Id>
<Manufacturer>REL</Manufacturer>
<Version>64</Version>
<ProductName></ProductName>
<Medium>Heat Cost Allocator</Medium>
<AccessNumber>30</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Units for H.C.A.</Unit>
<Value>1987</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2000-12-31T10:41:00</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2000-12-31</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Units for H.C.A.</Unit>
<Value>1302</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>1</StorageNumber>
<Unit>Time Point (date)</Unit>
<Value>2001-12-31</Value>
</DataRecord>
<DataRecord id="5">
<Function>Manufacturer specific</Function>
<Value>C0 01 01 0C</Value>
</DataRecord>
</MBusData>

@ -1,10 +1,11 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>1006089</Id>
<Manufacturer>SVM</Manufacturer>
<Version>9</Version>
<ProductName>Kamstrup SVM F22</ProductName>
<ProductName>Elster F4 / Kamstrup SVM F22</ProductName>
<Medium>Heat: Inlet</Medium>
<AccessNumber>148</AccessNumber>
<Status>70</Status>
@ -13,78 +14,97 @@
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (kWh)</Unit>
<Value>28014</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (m m^3)</Unit>
<Value>640581</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Volume (m m^3)</Unit>
<Value>640581</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (deg C)</Unit>
<Value>243</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (deg C)</Unit>
<Value>243</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (1e-1 deg C)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>On time (hours)</Unit>
<Value>6370</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Operating time (hours)</Unit>
<Value>6363</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume flow (m m^3/h)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="9">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="10">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Time Point (time &amp; date)</Unit>
<Value>2021-02-08T21:12:00</Value>
</DataRecord>
<DataRecord id="11">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>1</Device>
<Unit>Units for H.C.A.</Unit>
<Value>0</Value>
</DataRecord>
<DataRecord id="12">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Tariff>0</Tariff>
<Device>2</Device>
<Unit>Units for H.C.A.</Unit>
<Value>0</Value>
</DataRecord>

@ -1,3 +1,4 @@
<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>