<?xml version="1.0" encoding="ISO-8859-1"?>
<MBusData>
<SlaveInformation>
<Id>21050076</Id>
<Manufacturer>SPX</Manufacturer>
<Version>49</Version>
<ProductName>Sensus PolluTherm</ProductName>
<Medium>Heat: Outlet</Medium>
<AccessNumber>81</AccessNumber>
<Status>00</Status>
<Signature>0000</Signature>
</SlaveInformation>
<DataRecord id="0">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Energy (10 kWh)</Unit>
<Value>864</Value>
</DataRecord>
<DataRecord id="1">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Volume (1e-2 m^3)</Unit>
<Value>799892</Value>
</DataRecord>
<DataRecord id="2">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Unknown (VIF=0x7B)</Unit>
<Value>302</Value>
</DataRecord>
<DataRecord id="3">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Power (10 W)</Unit>
<Value>5458</Value>
</DataRecord>
<DataRecord id="4">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Flow temperature (1e-1 deg C)</Unit>
<Value>755</Value>
</DataRecord>
<DataRecord id="5">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Return temperature (1e-1 deg C)</Unit>
<Value>594</Value>
</DataRecord>
<DataRecord id="6">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Temperature Difference (m deg C)</Unit>
<Value>16076</Value>
</DataRecord>
<DataRecord id="7">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Fabrication number</Unit>
<Value>21050076</Value>
</DataRecord>
<DataRecord id="8">
<Function>Instantaneous value</Function>
<StorageNumber>0</StorageNumber>
<Unit>Customer location</Unit>
<Value>21050076</Value>
</DataRecord>
<DataRecord id="9">
<Function>More records follow</Function>
<Value></Value>
</DataRecord>
</MBusData>