initial
This commit is contained in:
49
.woodpecker.yml
Normal file
49
.woodpecker.yml
Normal file
@@ -0,0 +1,49 @@
|
||||
matrix:
|
||||
APP:
|
||||
- ui
|
||||
- api
|
||||
- abstraction
|
||||
- rules
|
||||
|
||||
env:
|
||||
NAMESPACE: "homea2"
|
||||
|
||||
steps:
|
||||
build:
|
||||
image: plugins/kaniko
|
||||
settings:
|
||||
repo: ${FORGE_NAME}/${CI_REPO}/${APP}
|
||||
registry:
|
||||
from_secret: container_registry
|
||||
auto_tag: true
|
||||
username:
|
||||
from_secret: container_registry_username
|
||||
password:
|
||||
from_secret: container_registry_password
|
||||
dockerfile: apps/${APP}/Dockerfile
|
||||
when:
|
||||
event: [push, tag]
|
||||
ref:
|
||||
exclude:
|
||||
- refs/tags/*-configchange
|
||||
|
||||
create_namespace:
|
||||
image: quay.io/wollud1969/k8s-admin-helper:0.3.4
|
||||
environment:
|
||||
KUBE_CONFIG_CONTENT:
|
||||
from_secret: kube_config
|
||||
commands:
|
||||
- kubectl create namespace ${NAMESPACE} || echo "Namespace ${NAMESPACE} already exists"
|
||||
when:
|
||||
- event: [tag]
|
||||
|
||||
configuration:
|
||||
image: quay.io/wollud1969/k8s-admin-helper:0.3.4
|
||||
environment:
|
||||
KUBE_CONFIG_CONTENT:
|
||||
from_secret: kube_config
|
||||
commands:
|
||||
|
||||
when:
|
||||
- event: [tag]
|
||||
|
||||
@@ -783,6 +783,23 @@ devices:
|
||||
set: "shellies/lichtterasse/relay/0/command"
|
||||
state: "shellies/lichtterasse/relay/0"
|
||||
|
||||
|
||||
- device_id: power_relay_caroutlet
|
||||
name: Car Outlet
|
||||
type: relay
|
||||
cap_version: "relay@1.0.0"
|
||||
technology: hottis_modbus
|
||||
features:
|
||||
power: true
|
||||
topics:
|
||||
set: "caroutlet/cmd"
|
||||
state: "caroutlet/state"
|
||||
|
||||
- device_id: powermeter_caroutlet
|
||||
name: Car Outlet
|
||||
type: threephase_powermeter
|
||||
cap_version: "threephase_powermeter@1.0.0"
|
||||
technology: hottis_modbus
|
||||
topics:
|
||||
state: "caroutlet/powermeter"
|
||||
|
||||
|
||||
|
||||
@@ -10,6 +10,9 @@ from packages.home_capabilities.temp_humidity_sensor import CAP_VERSION as TEMP_
|
||||
from packages.home_capabilities.temp_humidity_sensor import TempHumidityState
|
||||
from packages.home_capabilities.relay import CAP_VERSION as RELAY_VERSION
|
||||
from packages.home_capabilities.relay import RelayState
|
||||
from packages.home_capabilities.three_phase_powermeter import CAP_VERSION as THREE_PHASE_POWERMETER_VERSION
|
||||
from packages.home_capabilities.three_phase_powermeter import ThreePhasePowerState
|
||||
|
||||
from packages.home_capabilities.layout import (
|
||||
DeviceTile,
|
||||
Room,
|
||||
@@ -56,4 +59,5 @@ __all__ = [
|
||||
"get_scene_by_id",
|
||||
"load_groups",
|
||||
"load_scenes",
|
||||
"ThreePhasePowerState",
|
||||
]
|
||||
|
||||
29
packages/home_capabilities/three_phase_powermeter.py
Normal file
29
packages/home_capabilities/three_phase_powermeter.py
Normal file
@@ -0,0 +1,29 @@
|
||||
from pydantic import BaseModel, Field
|
||||
|
||||
class ThreePhasePowerState(BaseModel):
|
||||
"""
|
||||
State model for a three-phase power meter.
|
||||
|
||||
Required fields:
|
||||
- energy: Total energy in kWh
|
||||
- total_power: Total power in W
|
||||
- phase1_power, phase2_power, phase3_power: Power per phase in W
|
||||
- phase1_voltage, phase2_voltage, phase3_voltage: Voltage per phase in V
|
||||
- phase1_current, phase2_current, phase3_current: Current per phase in A
|
||||
"""
|
||||
energy: float = Field(..., description="Total energy in kWh")
|
||||
total_power: float = Field(..., description="Total power in W")
|
||||
phase1_power: float = Field(..., description="Power for phase 1 in W")
|
||||
phase2_power: float = Field(..., description="Power for phase 2 in W")
|
||||
phase3_power: float = Field(..., description="Power for phase 3 in W")
|
||||
phase1_voltage: float = Field(..., description="Voltage for phase 1 in V")
|
||||
phase2_voltage: float = Field(..., description="Voltage for phase 2 in V")
|
||||
phase3_voltage: float = Field(..., description="Voltage for phase 3 in V")
|
||||
phase1_current: float = Field(..., description="Current for phase 1 in A")
|
||||
phase2_current: float = Field(..., description="Current for phase 2 in A")
|
||||
phase3_current: float = Field(..., description="Current for phase 3 in A")
|
||||
|
||||
|
||||
# Capability metadata
|
||||
CAP_VERSION = "three_phase_powermeter@1.0.0"
|
||||
DISPLAY_NAME = "Three-Phase Power Meter"
|
||||
Reference in New Issue