modbus slave works, second adc added
This commit is contained in:
63
SimpleModbusSlave.h
Normal file
63
SimpleModbusSlave.h
Normal file
@ -0,0 +1,63 @@
|
||||
#ifndef SIMPLE_MODBUS_SLAVE_H
|
||||
#define SIMPLE_MODBUS_SLAVE_H
|
||||
|
||||
// SimpleModbusSlaveV7
|
||||
|
||||
/*
|
||||
SimpleModbusSlave allows you to communicate
|
||||
to any slave using the Modbus RTU protocol.
|
||||
|
||||
This implementation DOES NOT fully comply with the Modbus specifications.
|
||||
|
||||
Specifically the frame time out have not been implemented according
|
||||
to Modbus standards. The code does however combine the check for
|
||||
inter character time out and frame time out by incorporating a maximum
|
||||
time out allowable when reading from the message stream.
|
||||
|
||||
SimpleModbusSlave implements an unsigned int return value on a call to modbus_update().
|
||||
This value is the total error count since the slave started. It's useful for fault finding.
|
||||
|
||||
This code is for a Modbus slave implementing functions 3 and 16
|
||||
function 3: Reads the binary contents of holding registers (4X references)
|
||||
function 16: Presets values into a sequence of holding registers (4X references)
|
||||
|
||||
All the functions share the same register array.
|
||||
|
||||
Note:
|
||||
The Arduino serial ring buffer is 128 bytes or 64 registers.
|
||||
Most of the time you will connect the arduino to a master via serial
|
||||
using a MAX485 or similar.
|
||||
|
||||
In a function 3 request the master will attempt to read from your
|
||||
slave and since 5 bytes is already used for ID, FUNCTION, NO OF BYTES
|
||||
and two BYTES CRC the master can only request 122 bytes or 61 registers.
|
||||
|
||||
In a function 16 request the master will attempt to write to your
|
||||
slave and since a 9 bytes is already used for ID, FUNCTION, ADDRESS,
|
||||
NO OF REGISTERS, NO OF BYTES and two BYTES CRC the master can only write
|
||||
118 bytes or 59 registers.
|
||||
|
||||
Using a USB to Serial converter the maximum bytes you can send is
|
||||
limited to its internal buffer which differs between manufactures.
|
||||
|
||||
The functions included here have been derived from the
|
||||
Modbus Specifications and Implementation Guides
|
||||
|
||||
http://www.modbus.org/docs/Modbus_over_serial_line_V1_02.pdf
|
||||
http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b.pdf
|
||||
http://www.modbus.org/docs/PI_MBUS_300.pdf
|
||||
*/
|
||||
|
||||
#include "Arduino.h"
|
||||
|
||||
// function definitions
|
||||
unsigned int modbus_update();
|
||||
void modbus_configure(HardwareSerial *SerialPort,
|
||||
long baud,
|
||||
unsigned char byteFormat,
|
||||
unsigned char _slaveID,
|
||||
unsigned char _TxEnablePin,
|
||||
unsigned int _holdingRegsSize,
|
||||
unsigned int* _regs);
|
||||
|
||||
#endif
|