1 Commits
0.0.7 ... 0.1.0

Author SHA1 Message Date
2d9372ea38 change schema 2023-05-23 15:57:50 +02:00
2 changed files with 33 additions and 22 deletions

View File

@ -17,29 +17,39 @@ create table variable_t (
variable_id varchar(16) not null, variable_id varchar(16) not null,
label varchar(128) not null unique, label varchar(128) not null unique,
unit varchar(16), unit varchar(16),
quantity varchar(32),
unique (app, converter_id, device_id, variable_id) unique (app, converter_id, device_id, variable_id)
); );
create table measurement_t ( create table measurement_t (
time timestamp without time zone not null, time timestamp without time zone not null,
application varchar(128) not null, variable integer references variable_t (id),
variable varchar(128) not null,
unit varchar(16),
value float value float
); );
select create_hypertable('measurement_t', 'time'); select create_hypertable('measurement_t', 'time');
insert into application_t (app_id, label) values('ku226', 'Kupferdreher Str. 226, Essen'); insert into application_t (app_id, label) values('ku226', 'Kupferdreher Str. 226, Essen');
insert into variable_t (app, converter_id, device_id, variable_id, label, unit) insert into variable_t (app, converter_id, device_id, variable_id, label, unit, quantity)
values ((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'u', 'BHKW Spannung', 'V'), values ((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'u', 'BHKW Spannung', 'V', 'voltage'),
((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'p', 'BHKW Leistung', 'W'), ((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'p', 'BHKW Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'import', 'BHKW Energie Export', 'Wh'), ((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'import', 'BHKW Energie Export', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'export', 'BHKW Energie Import', 'Wh'), ((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'export', 'BHKW Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'u', 'PV Spannung', 'V'), ((select id from application_t where app_id = 'ku226'), '1', 'pv', 'u', 'PV Spannung', 'V', 'voltage'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'p', 'PV Leistung', 'W'), ((select id from application_t where app_id = 'ku226'), '1', 'pv', 'p', 'PV Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'import', 'PV Energie Export', 'Wh'), ((select id from application_t where app_id = 'ku226'), '1', 'pv', 'import', 'PV Energie Export', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'export', 'PV Energie Import', 'Wh') ((select id from application_t where app_id = 'ku226'), '1', 'pv', 'export', 'PV Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '3', 'mains', 'import', 'Netz Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'w1', 'p', 'Wohnung 1 Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'w1', 'import', 'Wohnung 1 Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'w2', 'p', 'Wohnung 2 Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'w2', 'import', 'Wohnung 2 Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'w3', 'p', 'Wohnung 3 Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'w3', 'import', 'Wohnung 3 Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'w4', 'p', 'Wohnung 4 Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'w4', 'import', 'Wohnung 4 Energie Import', 'Wh', 'energy'),
((select id from application_t where app_id = 'ku226'), '1', 'w5', 'p', 'Wohnung 5 Leistung', 'W', 'power'),
((select id from application_t where app_id = 'ku226'), '1', 'w5', 'import', 'Wohnung 5 Energie Import', 'Wh', 'energy')
; ;
@ -49,4 +59,5 @@ insert into variable_t (app, converter_id, device_id, variable_id, label, unit)
grant select on application_t to preprocessor; grant select on application_t to preprocessor;
grant select on variable_t to preprocessor; grant select on variable_t to preprocessor;
grant insert on measurement_t to preprocessor; grant insert on measurement_t to preprocessor;
grant select on measurement_t to grafana;

View File

@ -46,7 +46,9 @@ class DbOp(object):
select select
a.label as application, a.label as application,
v.label as variable, v.label as variable,
v.unit as unit v.quantity as quantity,
v.unit as unit,
v.id as vid
from application_t a, variable_t v from application_t a, variable_t v
where a.app_id = %(appId)s and where a.app_id = %(appId)s and
v.app = a.id and v.app = a.id and
@ -60,7 +62,9 @@ class DbOp(object):
variable = { variable = {
'application': res[0], 'application': res[0],
'variable': res[1], 'variable': res[1],
'unit': res[2] 'quantity': res[2]
'unit': res[3],
'vid': res[4]
} }
logger.debug(f"{variable=}") logger.debug(f"{variable=}")
return variable return variable
@ -78,14 +82,12 @@ class DbOp(object):
with conn: with conn:
with conn.cursor() as cur: with conn.cursor() as cur:
cur.execute(""" cur.execute("""
insert into measurement_t (time, application, variable, value, unit) insert into measurement_t (time, variable, value)
values (now(), %(application)s, %(variable)s, %(value)s, %(unit)s) values (now(), %(vid)s, %(value)s)
""", """,
{ {
'application': measurement['application'], 'vid': measurement['vid'],
'variable': measurement['variable'],
'value': measurement['value'], 'value': measurement['value'],
'unit': measurement['unit']
} }
) )
except Exception as e: except Exception as e:
@ -126,9 +128,7 @@ def mqttOnMessageCallback(client, userdata, message):
dbh = DbOp(config) dbh = DbOp(config)
variable = dbh.getVariable(appId, converterId, deviceId, variableId) variable = dbh.getVariable(appId, converterId, deviceId, variableId)
measurement = { measurement = {
"application": variable["application"], "vid": variable["vid"],
"variable": variable["variable"],
"unit": variable["unit"],
"value": float(payload) "value": float(payload)
} }