This commit is contained in:
2023-05-23 12:47:08 +02:00
parent 07f80924fd
commit 07efa32acb
3 changed files with 54 additions and 10 deletions

View File

@ -38,7 +38,6 @@ dockerize:
--name $CONTAINER_NAME
--restart always
--network internal-network
-e "APPLICATION_TENANT=$APPLICATION_TENANT"
-e "MQTT_LOGIN=$MQTT_LOGIN"
-e "MQTT_PASSWORD=$MQTT_PASSWORD"
-e "MQTT_BROKER=$MQTT_BROKER"
@ -49,12 +48,6 @@ dockerize:
$IMAGE_NAME:$CI_COMMIT_TAG
- docker network connect external-network $CONTAINER_NAME
deploy-saerbeck:
extends: .deploy
tags:
- saerbeck-deployment-only
environment:
name: saerbeck-production
deploy-berresheim:
extends: .deploy

52
schema/create-schema.sql Normal file
View File

@ -0,0 +1,52 @@
create database cem_monitoring;
-- create extension timescaledb;
create table application_t (
id serial not null primary key,
app_id VARCHAR(32) NOT NULL UNIQUE,
label varchar(128) not null unique
);
create table variable_t (
id serial not null primary key,
app integer references application_t(id),
converter_id varchar(16) not null,
device_id varchar(16) not null,
variable_id varchar(16) not null,
label varchar(128) not null unique,
unit varchar(16),
unique (app, converter_id, device_id, variable_id)
);
create table measurement_t (
time timestamp without time zone not null,
application varchar(128) not null,
variable varchar(128) not null,
unit varchar(16),
value float
);
select create_hypertable('measurement_t', 'time');
insert into application_t (app_id, label) values('ku226', 'Kupferdreher Str. 226, Essen');
insert into variable_t (app, converter_id, device_id, variable_id, label, unit)
values ((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'u', 'BHKW Spannung', 'V'),
((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'p', 'BHKW Leistung', 'W'),
((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'import', 'BHKW Energie Export', 'Wh'),
((select id from application_t where app_id = 'ku226'), '1', 'bhkw', 'export', 'BHKW Energie Import', 'Wh'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'u', 'PV Spannung', 'V'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'p', 'PV Leistung', 'W'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'import', 'PV Energie Export', 'Wh'),
((select id from application_t where app_id = 'ku226'), '1', 'pv', 'export', 'PV Energie Import', 'Wh')
;
-- create user preprocessor password 'geheim';
grant select on application_t to preprocessor;
grant select on variable_t to preprocessor;
grant insert on measurement_t to preprocessor;

View File

@ -66,7 +66,7 @@ class DbOp(object):
return application
except Exception as e:
logger.error(f"Error getting variable: {e}")
raise VariableNotFoundException(appId)
raise VariableNotFoundException(appId, converterId, deviceId, variableId)
finally:
if conn:
conn.close()
@ -155,8 +155,7 @@ REQUIRED_CONFIG_OPTIONS = [
'MQTT_PASSWORD',
'MQTT_BROKER',
'MQTT_PORT',
'MQTT_CA',
'APPLICATION_TENANT'
'MQTT_CA'
]
config = {}